Revolutionize Your Business with Machine Hub Software! Learn More
**More Information Upon Request**
All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Dust Level Sensors (capacitive) to ensure explosion isolation flaps are not compromised by a layer of dust accumulation on both dirty air inlets. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Explosion Isolation – 20″ Ø EXPLOSION ISOLATION FLAP VALVE(EV-VF) W/ LOCKING MECHANISM – DIRTY AIR TO COLLECTOR All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Explosion Isolation – 34″ Ø EXPLOSION ISOLATION FLAP VALVE(EV-VF) W/ LOCKING MECHANISM – CLEAN AIR DISCHARGE TO FAN All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Explosion Isolation Valve Control Panel. CP04 Standard panel includes status lights, intrinsic circuit with barrier and physical separation (1 per zone), monitored inputs, (3 total/2 programmable), ability to add a seconda(more…) All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Fan – 125HP Chicago Blower Fan with 20,000 CFM @ 30″ S.P. Exhaust to outside. 4,000 for primary CNC source collection x 2 and 6,000 CFM per enclosure secondary ventilation x2, or 20,000 CFM total. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Fire Suppression System – Mounted on dust collector, CO2 Type Detection System with three 35lb. CO2 Suppressant Tanks, Smoke detection, firebreak in-duct panels, and alarm switch. Pricing includes installation of syst(more…) All specifications are assumed to be correct but must be confirmed by the purchasing entity.,In-Duct Spark Detection System – Includes Infra-Red Spark Detectors in dirty air ductwork and automated extinguishing system. Requires connection to plant water supply. Pricing includes installation of detectors, contr(more…) All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – 3 Hopper Access Doors. Allows for access into hoper and underside of filtration section without having to remove rotary airlocks. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – Adder for 80 each, aluminized abrasion resistant spun-bond polyester cartridge filters with grounding straps All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – ATV-80 Clean Air Plenum (CAP) with outlet flange All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – ATV-80 Dirty Air Plenum (DAP) with flange All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – Dust Collector – Down-flow Vertical Collector: Model IVCDC-80, Complete with 80 each, Self-Cleaning Cartridge Filters, Tri-Hopper with 14″ Collars, Legs, Double valve reverse jet pulse cleaning. Includes E2T Turbo D(more…) All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – Explosion Rupture Panel Rated for < 200 Kst, 8 Bar Pmax pre-installed in dust collector sidewalls. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC Motor Controller – Model IPS2, 460V-125HP, NEMA 4X, Velocity sensor, programmed, fused disconnect, motor starter, variable frequency drive. Requires 3 phase connection and 3 phase back to motor. Wiring and mountin(more…) All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC No Loss Air Discharge Stack – Prevents rain from entering silencer and fan as clean air is exhausted to the atmosphere. IVEC Remote Activation & Interface HMI Panel – Requires 115V connection and mount by others. To be mounted on/near CNC enclosures. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Noise Silencer for Fan – 85dBA, 77dBA radiated noise. Requires external support – not included. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Over Pressure Kit – OPK Safety System to prevent duct damage in event of an overpressure condition. Requires mounting by others. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Rotary Airlock Motor Starters – 1HP – Electrical wiring not included. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Boss Rotary Airlock All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Ductwork Package – Clamp together ductwork package per specifications. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Dust collector service catwalk and access ladder – OSHA approved All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Dust discharge hose for rotary discharge airlocks and clamps. EZ Dump Dust Hopper – 1 cubic yard size hopper with fork truck lugs – design makes dust disposal easier. Equivalent of 12ea. 55 gallon drum capacity. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Heavy Gauge Duct Package – Post explosion isolation requirement – 6 ea. 5′ long flanged duct sections 20″ diameter for dual inlets. Three 34″ diameter flanged duct section post CAP to fan. Meets NFPA requirements. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Hopper Bin Full Assembly – Provides warning if dust collector hoppers get full and aren’t emptying correctly. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Interconnect Diagram IVEC – ATV Increase collector leg height to accommodate rotary airlocks and EZ dump dust hoppers. All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – Custom Paint Color for Collector All specifications are assumed to be correct but must be confirmed by the purchasing entity.,IVEC – Prewire solenoid to junction box on dust collector All specifications are assumed to be correct but must be confirmed by the purchasing entity.,Junior Control Panel to allow the three rotary air locks to be automatically controlled with the IPS-2 VFD. Ensures rotary airlocks are on when collector is on. Requires mounting and 115V connection by others. All specifications are assumed to be correct but must be confirmed by the purchasing entity. |
Customize Settings
Your Privacy Is Important To Us
Cookies are very small text files that are stored on your computer when you visit a website. We use cookies for a variety of purposes and to enhance your online experience on our website (for example, to remember your account login details).
You can change your preferences and decline certain types of cookies to be stored on your computer while browsing our website. You can also remove any cookies already stored on your computer, but keep in mind that deleting cookies may prevent you from using parts of our website.
Choose which cookies you want to enable or disable: